In-vitro validation of inertial-sensor-to-bone alignment
- authored by
- Ive Weygers, Manon Kok, Thomas Seel, Darshan Shah, Orçun Taylan, Lennart Scheys, Hans Hallez, Kurt Claeys
- Abstract
A major shortcoming in kinematic estimation using skin-attached inertial sensors is the alignment of sensor-embedded and segment-embedded coordinate systems. Only a correct alignment results in clinically relevant kinematics. Model-based inertial-sensor-to-bone alignment methods relate inertial sensor measurements with a model of the joint. Therefore, they do not rely on properly executed calibration movements or a correct sensor placement. However, it is unknown how accurate such model-based methods align the sensor axes and the underlying segment-embedded axes, as defined by clinical definitions. Also, validation of the alignment models is challenging, since an optical motion capture ground truth can be prone to disturbances from soft tissue movement, orientation estimation and manual palpation errors. We present an anatomical tibiofemoral ground truth on an unloaded cadaveric measurement set-up that intrinsically overcomes these disturbances. Additionally, we validate existing model-based alignment strategies. Modeling the degrees of freedom leads to the identification of rotation axes. However, there is no reason why these axes would align with the segment-embedded axes. Relative inertial-sensor orientation information and rich arbitrary movements showed to aid in identifying the underlying joint axes. The first dominant sagittal rotation axis aligned sufficiently well with the underlying segment-embedded reference. The estimated axes that relate to secondary kinematics tend to deviate from the underlying segment-embedded axes as much as their expected range of motion around the axes. In order to interpret the secondary kinematics, the alignment model should more closely match the biomechanics of the joint.
- External Organisation(s)
-
KU Leuven
Delft University of Technology
Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU Erlangen-Nürnberg)
- Type
- Article
- Journal
- Journal of biomechanics
- Volume
- 128
- ISSN
- 0021-9290
- Publication date
- 09.11.2021
- Publication status
- Published
- Peer reviewed
- Yes
- ASJC Scopus subject areas
- Biophysics, Orthopedics and Sports Medicine, Biomedical Engineering, Rehabilitation
- Sustainable Development Goals
- SDG 3 - Good Health and Well-being
- Electronic version(s)
-
https://doi.org/10.1016/j.jbiomech.2021.110781 (Access:
Unknown)